Home AC not blowing cold air? The short answer
An AC unit not blowing cold air usually has one of three problems: not enough airflow (a clogged filter, a frozen coil), no power to the outdoor unit (a breaker, the capacitor, the contactor) or not enough refrigerant (a leak). You can check the first ones yourself in about 15 minutes. The rest need a licensed tech, and the AC should stay off until then.
Often a quick fix
- Thermostat on Cool, fan on Auto
- A clogged air filter
- A tripped breaker
- Dust and ash on the outdoor coil
Needs a licensed tech
- A failed capacitor (the unit hums)
- A refrigerant leak
- A dead outdoor fan motor
- A stuck contactor or a worn compressor
AC not cooling? Check these six things first
They're safe for any homeowner, need no tools and take about 15 minutes. Go in order and stop at the first one that fixes it.
-
Set the thermostat right 1 minute
Set it to Cool, the fan to Auto and the temperature 3–5°F below the room. With the fan on On, it keeps blowing room-temperature air between cooling cycles, which feels like the AC has quit. A blank screen usually means dead batteries.
Give it 5 minutes after any change: many systems wait a few minutes before the compressor restarts.
-
Check the air filter 2 minutes
It sits behind the return grille or in a slot on the furnace or air handler. If it's gray and you can't see light through it, replace it. A clogged filter starves the indoor coil of air, the coil ices over and the vents blow warm.
New filter, still warm air? The coil may already be iced. See step 5.
-
Check both breakers 2 minutes
Central AC has two: one for the indoor unit (the furnace or air handler) and a double breaker for the outdoor unit. Reset a tripped one once: switch it fully off, then on. Also check the shutoff box on the wall next to the outdoor unit.
Trips again? Stop here. A breaker that trips twice points to a short, a failing capacitor or a worn compressor.
-
Look at the outdoor unit 3 minutes
While the AC is calling for cooling, the fan on top should spin and the compressor should hum. Clear leaves and plants back about 2 feet. Fins caked with dust or ash? Turn the power off at the shutoff box and rinse them with a garden hose on a gentle spray, never a pressure washer.
Hums, but the fan won't spin? Turn the AC off. It's usually the capacitor. AC fan not spinning
-
Look for ice 2 minutes
Check the larger copper line at the outdoor unit and, if you can see it, the indoor coil above the furnace. Frost or ice means the coil froze. Turn cooling off and the fan to On to thaw it; that can take a few hours. Never chip the ice.
Ice came back after a full thaw? That often means low refrigerant. Frozen AC coil
-
Measure the temperature split 15 minutes
Let the AC run 15 minutes. Hold a kitchen thermometer at a return grille, then at the supply vent closest to the indoor unit. A healthy system blows air about 15–20°F colder than it pulls in. Under 10°F points to low refrigerant, a weak compressor or an airflow problem.
Good split, house still warm? On a 105°F Valley afternoon even a healthy AC can run nonstop and hold only the high 70s. Leaky attic ducts lose cold air too.
AC running but not cooling after all six checks?
A licensed tech finds the cause and writes down the price before any work. We call back within 30 seconds.
Air conditioner not blowing cold air but running? Here's what it usually is
Most home AC not cooling problems come down to one of these, quick fixes first. The ones you can fix cost nothing or the price of a filter. For the rest, a tech finds the cause and gives you a written price before any work. See typical repair prices
- Thermostat setting. Fan on On, the wrong mode, or dead batteries. Step 1You can fix it
- Clogged filter. Weak airflow from the vents, and the coil can ice up. Step 2You can fix it
- Tripped breaker. Nothing runs outside. Reset it once; if it trips again, call. Step 3You first, then a tech
- Dirty outdoor coil. Dust and ash block the fins, so the AC can't shed heat. Step 4You can rinse it
- Frozen coil. Ice on the lines, weak warm air, water when it melts. Frozen AC coilThaw it, then a tech if it returns
- Failed capacitor. The unit hums, but the fan or compressor won't start. Fixed with an AC capacitor replacement.Needs a tech
- Refrigerant leak. Warm air, ice, a hiss. It needs refrigerant leak repair, not just a top-off.Needs a tech
- Outdoor fan motor. The fan on top stopped and the unit runs hot. AC fan not spinningNeeds a tech
- Stuck contactor. The outdoor unit won't start, or won't shut off. Request a techNeeds a tech
- Worn compressor. A loud hum, a tripping breaker, the fan runs but nothing cools. AC compressor repairNeeds a tech
- Clogged drain line. A full drain pan trips the float switch and shuts the AC off. AC leaking waterYou first, then a tech
- Leaky attic ducts. Cold at the unit, warm in the far rooms. DuctworkNeeds a tech
Not sure which one it is? That's what the diagnosis is for: the cause in plain words, then the price. More on AC repair.
AC not cooling house in a heat wave? Why it happens in Los Angeles
Valley heat waves
On 100°F+ days the AC runs for hours without a break. Weak capacitors and tired compressors fail first. In the Valley, see AC repair in Van Nuys and Woodland Hills.
Attic air handlers
In many LA homes the indoor unit and the ducts sit in an attic that passes 130°F. A leaky duct there cools the attic, not you.
Santa Ana dust and ash
Wind and wildfire ash clog filters and outdoor coils in days. Check the filter after every windy week.
Older R-22 systems
Units from before 2010 often run on R-22. It hasn't been made since 2020, so a leak on one is the moment to compare a new AC.
A spring tune-up catches most of this before the first heat wave. HVAC maintenance
My AC is not cooling: questions, answered
Why is my AC running but not cooling the house?
Most often it's a clogged filter, a frozen coil, a dirty outdoor coil or a failed capacitor that stops the outdoor unit. HVAC not blowing cold air even though the thermostat, the filter and the breakers check out? Then the cause is usually inside the unit: refrigerant, the capacitor, the fan motor or the compressor. Those need a licensed tech.
Is it safe to keep running an AC that blows warm air?
Not for long. An air conditioner not cooling because the outdoor fan won't spin, or because the coil keeps icing, can overheat or flood the compressor, the most expensive part. Turn cooling off until it's checked.
How cold should the air from the vents be?
About 15–20°F colder than the air going into the return. If your home AC is not cooling and the split is under 10°F, the problem is usually the refrigerant, the compressor or the airflow.
Can I add refrigerant myself?
No. Only an EPA-certified tech can handle home AC refrigerant, and a low charge always means a leak. Topping it off without finding the leak only puts off the next breakdown. Refrigerant leak repair
My AC stopped cooling after a power outage. What now?
Reset both AC breakers once, set the thermostat to Cool and wait 5–10 minutes: many units hold the compressor off for a few minutes after the power comes back, and some thermostats lose their settings. If the outdoor unit still won't start, call us.
Why does my AC cool at night but not in the afternoon?
On a hot afternoon the system works at its limit, so a dirty outdoor coil, a slightly low charge or an undersized unit shows up first. If the temperature split is good, it's the heat. If it isn't, have it checked.
How much does AC repair cost in Los Angeles?
The service call is $50, credited toward the repair. After the diagnosis you get a written price before any work, and repairs carry a 1-month parts and labor warranty. See typical repair prices
Heater not blowing hot air in house either?
A heater not blowing hot air is a different problem, usually the thermostat, the filter, the igniter or the flame sensor. A furnace not blowing hot air has its own checks. Furnace not working or blowing cold air
Central air not cooling in some rooms only?
That's usually airflow: closed or blocked vents, a crushed or loose duct in the attic, or a system too small for the house. A tech can check the airflow room by room. Ductwork
Commercial AC not cooling?
We repair rooftop and package units for offices, shops and restaurants. A commercial AC unit not cooling gets the same first checks: the thermostat, the filter and the breaker. Then call (323) 736-3737. Commercial HVAC