Furnace not working or blowing cold air? Start with six safe checks.

After nine months off, a furnace often won't heat for a simple reason: a thermostat setting, a clogged filter, a switch or a dirty flame sensor. Here's how to check each one safely, what it usually is when they don't help, and which parts need a licensed tech. Smell gas? Leave the house first.

An Orion HVAC technician watches a furnace igniter glow while diagnosing a furnace that won't heat

Heater blowing cold air, or not heating at all? The short answer

Cold air from the vents? Check the thermostat first: with the fan on On, it blows room air even when the burners are off. Nothing runs at all? It's usually power: a breaker, the furnace switch or the panel door. It starts, clicks and quits? Usually the igniter or a dirty flame sensor, a job for a tech. An older furnace with a pilot light may just need relighting by the label.

Often a quick fix

  • Thermostat on Heat, fan on Auto
  • A clogged filter from AC season
  • The furnace switch, breaker or panel door
  • A pilot light that went out (older furnaces)

Needs a licensed tech

  • The igniter or the flame sensor
  • The inducer motor or pressure switch
  • A limit switch that keeps tripping
  • The blower motor or the control board

Home heater not working? Check these six things first

Safe for any homeowner, no tools, about 15 minutes. Don't open the burner compartment or work on the gas line.

  1. Set the thermostat to Heat 1 minute

    Set it to Heat, the temperature 5°F above the room and the fan to Auto. With the fan on On, the blower runs nonstop and pushes cold air between heating cycles: the most common reason a heater seems to blow cold air. A blank screen usually means dead batteries.

    Give it a few minutes: the furnace runs its draft fan and lights the burners before the blower starts.

  2. Check the filter 2 minutes

    The same filter served the AC all summer. Clogged, it chokes the airflow, the furnace overheats and a safety switch shuts the burners off, so the fan keeps blowing cold. Replace it if you can't see light through it.

  3. Check the switch, the breaker and the panel 2 minutes

    Next to the furnace there's usually a switch that looks like a light switch: it must be on. Check the furnace breaker in the panel. And the front panel must sit fully in place: a safety switch behind it keeps the furnace off when it's loose.

  4. Check the gas, without forcing anything 2 minutes

    Does the stove light? Then the house has gas. At the furnace, the handle on the gas valve should run along the pipe, not across it. Never force a valve, and if you smell gas, stop and leave the house.

  5. Relight the furnace pilot light (older furnaces) 5 minutes

    Most furnaces made since the 1990s have no pilot: an igniter lights the burners. If yours has a small standing flame behind a little window and you smell no gas, follow the relighting steps printed on the furnace label, exactly as written.

    Won't stay lit? That's usually the thermocouple, a job for a tech.

  6. Read the status light 2 minutes

    Most modern furnaces have a small blinking light you can see through a window in the panel. Count the blinks and match them to the chart on the panel door. Tell the office the code when you call: it saves time on the visit.

    A code for the flame sensor, igniter or pressure switch? Those need a tech.

Heater not working in house after all six checks?

A licensed tech finds the cause and writes down the price before any work. We call back within 30 seconds, day or night.

Request a tech

Furnace not igniting or blowing cold air? Here's what it usually is

Quick fixes first. For anything that needs a tech, you get a safety check and a written price before any work. See typical repair prices

  • Thermostat or fan setting. Fan on On, the wrong mode, or dead batteries. Step 1You can fix it
  • Clogged filter. The furnace overheats, the limit switch shuts the burners off, the fan blows cold. Step 2You first, then a tech if it repeats
  • Dirty flame sensor. The burners light, then shut off in seconds. Common after nine months off.Needs a tech
  • Failed igniter. It clicks or hums, but no flame lights.Needs a tech
  • Pilot out or thermocouple. Older furnaces: the pilot went out, or won't stay lit. Step 5Relight it, then a tech
  • Inducer or pressure switch. A whine or a rattle, and the burners never light.Needs a tech
  • Blower motor. The burners light, but little or no air reaches the vents.Needs a tech
  • Clogged condensate drain. High-efficiency furnaces shut down when their drain backs up.Needs a tech
  • Control board. No signs of life, or the furnace acts at random.Needs a tech
  • Failed thermostat. Blank screen with new batteries, or it never calls for heat. Fixed with a repair or a thermostat installation.Needs a tech
  • Wall heater or floor furnace. Gas heater not working in an older home? A pilot or thermocouple, usually. Wall heater repairNeeds a tech
  • Cracked heat exchanger. Found on the safety check. A carbon monoxide risk that means a new furnace.Needs a tech

Not sure which one it is? That's what the diagnosis is for: the cause in plain words, then the price. More on furnace repair.

Why heaters fail in LA homes: it's rarely the cold itself

Nine months off

Most LA furnaces sit unused from spring to fall. Dust settles on the flame sensor and the burners, so the first cold night they won't stay lit.

Cold foothill nights

In the foothills winter nights get close to freezing and heaters run for hours. Weak parts fail there first. See furnace repair in La Crescenta and Pasadena.

A filter from AC season

After a summer of AC and Santa Ana dust, the filter is often the whole problem. Change it before you turn the heat on.

Older heaters

Many 1940s–60s homes still heat with gas wall heaters and floor furnaces. Wall heater repair

A fall tune-up checks the burners, igniter, flame sensor, venting and safety controls. HVAC maintenance

My heater is blowing cold air: questions, answered

My furnace is blowing cold air. Why?

A furnace blowing cold air most often has its thermostat fan set to On, so it blows between cycles. If the burners light and then quit, it's usually a dirty flame sensor or a clogged filter tripping the limit switch. If they never light, it's the igniter, the gas supply or the pressure switch.

My heater is not working at all, not even the fan?

Then it's power or the thermostat. Check the batteries, the furnace switch, the breaker and the front panel. If all of that is fine, the control board or a safety switch has cut the power, and a tech can test it.

How do I relight a furnace pilot light?

Only older furnaces have one. If you smell no gas, follow the steps on the label inside the furnace door: usually turn the knob to Pilot, hold it down while you light it, keep holding for about a minute, then turn it to On. If it goes out when you let go, the thermocouple is the usual cause. Smell gas? Don't light anything.

My furnace won't turn on after the summer. Is that normal?

It's common in LA. After nine months off, dust settles on the flame sensor and the burners, and the switch or the gas valve may have been turned off. Go through the six checks; if it still won't start, book a repair or a fall tune-up.

The furnace clicks but won't light. What's wrong?

The clicking is the ignition trying. If no flame follows, it's usually the igniter, the gas supply or a safety switch. Don't keep resetting it: after a few tries most furnaces lock themselves out. Call a tech.

Is a burning smell normal the first time the heat runs?

A dusty smell for the first few minutes after months off is normal. A smell that lasts, smells electrical or comes with smoke is not: turn the furnace off at its switch and call.

My carbon monoxide alarm went off. What do I do?

Get everyone outside into fresh air and call 911. Don't go back in until the fire department or SoCalGas says it's safe, and have the furnace checked before you use it again.

Do you fix gas wall heaters and floor furnaces?

Yes. Many older LA homes still heat with them. If one isn't safe to keep running, the tech tells you plainly. Wall heater repair

How much does furnace repair cost?

The service call is $50, credited toward the repair. After the diagnosis and the safety check you get a written price before any work, and repairs carry a 1-month parts and labor warranty. See typical repair prices

Do you offer emergency heating repair?

Yes. Call (323) 736-3737: we call back within 30 seconds, day or night, and the office tells you how soon a tech can come. Emergency HVAC repair

About Orion HVAC. A licensed heating and air conditioning contractor in Los Angeles since 2018 (CSLB #1079927), with offices in Van Nuys and La Crescenta. We wrote this from the furnace calls our techs run every winter.

About us  ·  Reviews

879 Google reviews.
792 of them five stars.

And 150 more on Yelp, rated 4.9. Read what homeowners across LA, the Valley and Santa Clarita say.

Nydia CooperFurnace repair
“Orion HVAC replied immediately to my request for service, arriving on the day I made the request. Yuri was prompt and professional, quickly identifying a furnace component that required replacing at a fair and modest price.”
Leo ChuAC repair
“They were the second company to come out to check my AC. The first one made up some crazy reason for failure. But Orion turned out to be great! … the tech Egor was very nice, knowledgeable, and straightforward.”
Oleh RudoiNew AC installation
“Great service! I can’t believe they finished installation in one day! Any other company I called offered 2-3 days for installation. … Yuri and Tim did a great job, and they were pleasant to communicate.”

Still cold inside?
Get a call back in 30 seconds.

A $50 visit with a safety check, credited toward the repair. Emergency service is available, day or night.

Request a tech

Leave your phone. We call you back within 30 seconds, day or night.

We call back in 30 seconds Or call (323) 736-3737
Request receivedWe'll call you back within 30 seconds. In a hurry? Call (323) 736-3737